Series RLC impedance magnitude
Sinusoidal response combines resistance and net reactance.
Key knowledge
The steady sinusoidal response of an ideal series RLC circuit has impedance magnitude |Z| = √[R² + (ωL − 1/(ωC))²], and current amplitude I₀ = V₀/|Z| when |Z| > 0.
Values and equations
|Z| = √[R² + (ωL − 1/(ωC))²]; I₀ = V₀/|Z|
- Z, R
- Impedance magnitude and resistance Ω
- L
- Inductance H
- C
- Capacitance F
- ω
- Drive angular frequency rad s⁻¹
- I₀
- Current amplitude A
- V₀
- Voltage amplitude V
Conditions and scope
- Linear constant R ≥ 0, L > 0, C > 0; angular frequency ω > 0 and transients removed.
- This is an amplitude relation, not a complex-phasor sign convention or a parallel-circuit formula.
Sources · 1
References
Sources retain their recorded scope. A source link alone does not establish verification of every statement.
Evidence and review
Series reactances, equation 15.13 impedance magnitude and amplitude relation.
2026-10-10 · Ideal series steady response only; lossless zero-impedance resonance is excluded from division.
Entry details
Permanent link to this entry ↗- Record identity
- physics-ac-impedance
- Revision
- university-reference.1
- Structured reference record